Filters clean. Are you sure the used one was good? To the left is an example of a rusty impeller magnet. I no longer get the E02 error code once I removed those pieces of debris. Sometimes on power, sometimes the pump will run for 10 seconds, sometimes 5 minutes. Heat is working fine. "url": "https://lesliespool.com/", In some cases, the errors that pop up require replacement parts in order to fix the root of the problem. Get help with your Lay-Z-Spa pump. Power Problems Step 1 Reset power to the spa. When I turn heater on, E02 error right away, within 2 seconds. The stopper caps are still inside the spa. We can review your products on our channel. "identifier": "" Thanks for viewing. A buildup of dirt and other things on the filters can slow the flow of water through the system. If this is the case, sometimes a quick smack, not too hard, to the side of the pump will get the paddle to drop into the normal position. Place the stopper caps inside the spa, disconnect the pump unit, and bring the pump unit inside to cool down. Cleaned egg ports. These can come in powder or liquid form. If you have a Coleman Saluspa and are getting an e02 code error, dont worry. If you can see dirt and debris around that you need to clean it. So the issue was with the thermometer inside of the pump reading closer to ambient air temps (20F) due to it not running overnight. Overheat; high temperature condition, over 110F. An ounce of prevention is worth a pound of cure. Coleman Saluspa Error Code E03 - AreaViral We can review your products on our channel. My fix was a lot easier and quicker and since I didn't see any videos on this, I thought I would try and help out others that have this problem. Sometimes, depending on conditions, the water flow sensor paddle can get a buildup of dirt and debris on it that will prevent it from moving to the correct position when water is flowing. Instantly? "author": { Flushing vents did the job. Coleman Saluspa Error Codes Download E03 Swipe, Coleman Saluspa Error Codes How To Remove Them. You will need to remove the cover to access the sensor. floodstop flashing green lights 0 Menu Close. what was the louvre before it was a museum. Create your own unique website with customizable templates. E02 comes up as soon as push pump. The pump does not seem to turn on now quickly followed by E02 code. 110-120V60Hz, 12A at 20C. These affect how often the spa operates. The date of the spa pump can be located on the silver sticker on the pump body itself (S/N Number) or engraved within the handles. Keep reading and we'll have your tub back up and running in no time. As long as the water is above the two filter inlet pipes and at least half way to the outlet pipe, you should be able to get water to flow. Opened up and checked magnet flow disk. Lets start at the top, todays post is about water flow trouble codes on your spa panel. }, 2001-2002 Coleman Spas 700 Series Owners Manual. The E03 code indicates it is too cold to operate. . I changed and cleaned the filters after every use without fail. Coleman Spa Lights. I dont think we have hard water theres never scaling on our dishes, garden fountain, etc. Required fields are marked *. My hot tub randomly shut off last night due to Error 02, which happens every now and then. You might see few other error codes on your Coleman Lazy Spa control panel like lazy spa E08, lazy spa E03, And lazy spa E02. Try different types of CDs; a new music CD would be the best to try. Look inside the top hose connector and you should see the flow sensor paddle hanging down. 5-10 seconds.. Coleman Hot Tub Parts. Part of being prepared is knowing what you are dealing with. Then I disconnected the power lines going to the bus bar and the control board. So, why does my hot tub keep tripping and turning off? Replace the cover being sure to connect the ribbon cable if you had it disconnected. we usually leave it on all the time. Contact us here for business partnerships: ascentcreativellc@gmail.com, #Coleman #Saluspa #Error #Code #E03 #Fix AreaViral, Your email address will not be published. "address": "", Putting a good bit of this solution in the descaler and turning the pump and heater on for 15 to 30 minutes will break up and disolve the limescale buildup and get you back running quickly. Here in this setup guide, I have laid out the Coleman SaluSpa Set up instructions in easy to follow 7 steps. If the filters are too dirty, they may require replacing. im at a loss can you help me. Gasket on water sensor housing is new and not leaking. "@type": "ImageObject", Ive got an externally pumped tub with better flow rate/heating an extra filter and its still controlled by the egg. Enter your email address to subscribe to my blog and receive notifications of new posts by email. dbemowsk (at) phpwebscripting.com if you dont want to post it in the comments. The water flow sensor is a tube that has a small paddle that contains a small magnet that hangs in the water's path, and when water flows through the tube, the paddle is pushed upwards causing the magnet to trigger a magnetic switch. Let's start at the top, today's post is about water flow trouble codes on your spa panel. grrrr.. yeah ill have to dig into it with a multimeter. The partially shorted power lead is a possibility. This paddle is supposed to lift up and trigger a sensor to tell the system that water is moving when the pump is turned on. Coleman SaluSpa Hot Tub! Water Flow Error Filter cartridges are dirty Remove the filter cartridges from the pump and press the filter or heat button. Coleman Saluspa Error Codes Download E03 Swipe Please contact us for more help with this E02 Error Code Troubleshooting download E03 swipe Description Cause Solution Temperature too low Normally caused when the Lay Z Spa pump has been used in temperatures below 4C. If you live in an area with hard water you are no stranger to limescale. #COLEMAN SALUSPA ERROR CODES E03 HOW TO# How To Stop My Hot Tub Keep Beeping And Cutting Out E02 Warning The pump housing displays an E02 warning which will cut off the pump and heating system, or the housing just cuts out altogether. As an alternative, a spa may be installed within 5 feet of metal surfaces if each metal surface is permanently connected by a minimum 8 AWG (8.37 mm2 ) solid copper conductor to the wire connector on the terminal box that is provided for this purpose. High limit sensor may be shorted or disconnected, Panel buttons pressed to many times or too quickly. Once you found the best location clean the area and spread the ground cloth of Coleman Inflatable hot tub. Once it is flowing and you can turn the pump on, let it run for the 15 to 30 minutes and you should be set. One EASY way to tell if this is your issue is to remove the filter housings and start your pump. My Coleman Saluspa has an E03 code JA: I'll do all I can to help. "height": "500", IMPORTANT: Before you restart the pump, press the reset button. Any modification that increases the flow rate of the circulation system shall require re-evaluation of the cover/grate and sump to ensure that the flow rating of the Suction Outlet Fitting Assembly (SOFA) is not exceeded. Remove the stopper caps before heating your Lay-Z-Spa. If this error code does become visible, please contact your Bestway Warranty Department as the pump will need to be either replaced or repaired. Pump runs fine. If you make a purchase, you help support our channel through a small commission at no extra cost to you. I then purchased an external bestway 1000gph pool pump unit. I also have a really nifty mod youve probably be interested in. Coleman Spa Plumbing. Attach the stopper caps to the inside of the liner and then remove the Lay-Z-Spa pump unit from the liner (you can do this by unscrewing the 3 couplings A, B and C). I am totally lost here.. What is the next step? Some system status codes are identified as well, with the phrase "system message, not an error.". Once done, press the heater button. You can find the bottom outlet valve near the bottom interior of the Lay-z-Spa. Is it to replace both the waterflow sensors? When inflating the lid I did by accident turn on the pump without water in it. I have checked all lines/tubes and they are not clogged. There may be a number of reasons why your heater pump is displaying an error code. Good Luck! Thank you! I have a few hot tubs I rent out at the weekends, the hardwater was an absolute nightmare when I started out, I bought a descaler from easytubs.co.uk and its the best device I have bought, I descale the tubs once a month for a few minutes and it keeps the E02 error at bay. Not leaking water, but somehow shorting out. You should also clean the filter cartridges on a regular basis to keep your inflatable hot tub water clean. Edgar Payne Composition Of Outdoor Painting Pdf, Mafikizolo Van Toeka Af Album Download Zip, Velamma Episode 14 Free Download Pdf In Hindi, Harrison Medicina Interna 18 Descargar Gratis Pdf, Kaisi Yeh Judai Hai Aankh Bhar Meri Aayi Hai Mp3 Song. No need to be fancy, just an overview. coleman saluspa error code e03 9, 09. Panel lock; enter code to unlock control panel. hello dan, i reached out to you ask you a question , my Eo2 error code came up . First, put your hot tub cover back on and let the heater do its job for about 24 hours. Oct 28, 2015 - Each MAAX Spas hot tub is made with three layers of insulation, a 56. Water should go through pipe B and come out of pipe C. These bits can get on and into various things and cause problems. Press the thermal reset button using a pencil or screwdriver (see. Find the problem quickly so you can fix your hot tub." IMPORTANT: Before you restart the pump, press the reset button. One of the main causes of this is broken plastic around the magnet that causes the magnet to get wet and rust. If blinking, spa is shut down. Some other brands are lime-away and CLR. Buy the Coleman Saluspa on Amazon: https://amzn.to/3WJ5PlP. 3 0 obj Attach the second filter casing in the same way. Coleman SaluSpa Hot Tub! The error happens with and without the filter installed. Carrying out regular checks and maintenance can prevent persistent pump problems so you can get back to enjoying your Lay-Z-Spa. Is there a replacement pump available? I am having an e02 issue with mine. Remember there is 2 1/2 feet of water pressure above that port so it should rush out really well. SaluSpa Madrid AirJet Inflatable Hot Tub with App Control 2-4 person. When you push the filter button, do you hear the pump run for a couple seconds before getting the E02 error? No obstruction in outlet port. Sign up now. Is that accurate? Any idea what size rigid pipe do you know? 1997 . Let's go through them now. The overall performance, durability, and comfort of your home sauna are significantly influenced by the materials used in its construction. For More Information How to Trouble Shoot And What are The Reasons behind the error codes shown, we are providing a pdf guide about the Coleman Spa Troubleshooting error code. stream If the valve is opened rotate and twist the valve to close it. So now its just flow-through. Believe it or not, your filters being dirty can actually cause this error. Broken, Stuck or Damaged Impeller or Impeller Shaft. Coleman SaluSpa Setup And Lazy Spa E02. Cheiftan Residence Willie Residence Brown. Its then followed by the EO2 error. Sounds like just enough that once there is a minor flow issue with a dirty filter, it trips the flow sensor. Hi Dan, I ordered one of your replacement water sensor paddles and it works great! On some models it is the piece that your ChemConnect attaches to. "description": "This great big list of spa and hot tub error codes helps you troubleshoot spa problems at home. Read your blog. Remove the filter cartridge and clean it with a hose. 2 0 obj Use the arrow keys to regulate the water temperature. If the water temperature added to the Hot Tub and PCU was over 116 F. If this is the cause then drain the hot water and add cold water enough to lower the temperature below 104 F. Filling the Hot Tub directly . So, you have got to know about the Coleman SaluSpa setup process and also troubleshooting the potential error codes. SaluSpa Zurich AirJet Inflatable Hot Tub with EnergySense Cover 2-4 person. 2. You should be back running. If you try to start your water pump with no water in the tub or with the water level below the filter inlets, you will get this error. Find many great new & used options and get the best deals for Salusap Airjet Pumps All Layzspa Package Service Descaler - at the best online prices at eBay! 2001-2002 Coleman Spas 700 Series Owners Manual. Plug the pump unit directly into a mains socket and not into an extension lead. I can take off the upper half of the egg to get to all blower/heater/PDUnit(my term) but the pump seems to be below the tray. Ive tried with a twisting motion but nothing happens. I have backflushed the system a few times to make sure water is flowing, so I gather its a pump issue. Unplug the pump unit, lightly strike the side of it and then plug it back in. Every digital spa control is designed with some diagnostics, to self-diagnose problems with pumping and heating your spa or hot tub. "url": "https://i8.amplience.net/i/lesl/LES00004-Leslie's-Logo-Refresh_Final_FullColor_Outlines_Crop" Find out the causes and the solutions to pump error codes, noisy pump issues, heating problems and much more. All rights reserved. It will be the black cube mounted to the right of the water flow sensor recessed into the platform that things are mounted on. "@type": "Person", The Lay-Z-Spa is not designed to operate with water temperatures exceeding 40C (104F). If you live in an area of hard water you should do this a couple times per year to prevent these problems. With the paddle stuck in the up position, the system assumes that it cannot accurately detect water flow and will display an E01 error. 1 Bestway SaluSpa 2 Warning 3 Installation 3.1 Selected Location 3.2 GFCI Test 3.3 Assembly part refer to the provided installation leaflet. Free shipping for many products! Replacing the paddle fixed my problem for a while but once again, the E02 error is back. Use Up and Down arrow keys to navigate search results. If the system sees that the flow sensor is triggered immediately upon startup, it assumes that the paddle is stuck in the up position. i have the same E02 code once i plug the pump in the GFCI plug trips instantly. Coleman 6-Person 60-Jet Round Inflatable Hot Tub in the. "@type": "Organization", Read also: How To Fix Netflix Error Code NW-4-8 - AreaViral. havent figured out the heating yet. I have the lazy spa moldives, it runs fine untill i put the heater on and filter then i get e02 error code. Power board; check topside and remote panel connections to power board, Power supply interrupted, unit running on battery backup, Service technician's test plug connected; system message, not an error, Panel error; communication error between panel and circuit board, Priming pump is starting; system message, not an error, High limit sensor failure; temperature sensor fault, Standby mode; system message, not an error, Self-cleaning filtration mode; system message, not a an error, Spa in standard-in-economy mode; system message, not an error, Sensor open or disconnected; heater disabled but spa operational, Sensor short, nonfunctional; heater disabled but spa operational, Temperature sensor fault, heater deactivated, Sensors out of balance, reporting different results, Sensor plugged into jack A is not working, spa is shut down, Sensor plugged into jack B is not working, spa is shut down. 1997-2000 Coleman Spas/ Cal Cooperage 100 Series Owners Manual. The Power Saving. I see whole eggs put of stock but really think I just need pump. Air blower runs fine. May 16, 2017 - En. The unit turns on and the pump runs fine, no errors or excessive noise. Since Coleman Lay z spa hot tub is the best of the two with over 1100 customer reviews on Amazon. If your filters are old or dirty, it makes all the other problems worse. Water Flow Error Water flow sensors not working If the above troubleshooting has not resolved the problem, the water flow sensors may not be working. Each company uses its own conventions for naming the various system faults. Clean and dry your hot tub with a cotton cloth. This site will focus on Swimming, Pools, Home Spas, Saunas, Hot Tubs and any way you can think of to relax and unwind. Also for: Saluspa 54130e, Saluspa 54155e, Saluspa 54157e,. My name is Dan Bemowski, and this is my new WordPress website started on June 11th 2017, Click to share on Twitter (Opens in new window), Click to share on Facebook (Opens in new window).